Specification of Partech TurbiTechw² HR Suspended Solids Sensor Murah
TurbiTechw² HR Suspended Solids Sensor
The TurbiTechw2 HR Sensor has been specifically designed for use in wastewater treatment systems where high levels of suspended solids are desirable in the aeration phase. Membrane Batch reactors typically run with MLSS values in the region of 8,000 to 14,000 mg/l. MLSS concentrations promote numerous process benefits, including stable operation, complete nitrification, and reduced biosolids production reducing biological volume requirements (and associated footprint) to only 20–30 percent of conventional biological processes. Further, the membrane tanks provide extremely space efficient solids separation and do not require a clarifier in the system.
The TurbiTechw2 HR sensor is suitable for monitoring solids in higher ranges than the standard LA version of the sensor due to it's shorter path length. The large optical surface and sample volume combine to ensure that the sensor is providing information that is reliable and representative of the solids present in the process. Deposits of fats and grease on the sensing area do not prevent the sensor from measuring unlike sensors with small optical surfaces.
In addition the sensor incorporates a self cleaning mechanism that ensures that the optical surfaces are kept clean at all times, the cleaning system is designed to avoid problems with ragging and does not smear the optical system. The cleaning system ensures that manual intervention on a routine basis is not required, the sensor should simply be checked as part of general site housekeeping.
APPLICATIONS
- Membrane Batch Reactors
- Mixed Liquor
- Returned Activated Sludge
- Surplus Activated Sludge
MEASUREMENT PRINCIPAL
- Light Attenuation
- Wavelength 860nm
FEATURES
- Fully automatic Self Cleaning
- Flexible Mounting System
- Large Optical Surface
BENEFITS
- Automated Aeration Control
- Low Cost of Ownership
COMPATIBLE MONITOR
ALTERNATIVE SENSORS
- TurbiTechw2 LA
- SoliTechw2 IL
SPECIFICATION DATA
Physical
|
Dimensions (hxwxd)
|
Ø80mm, 470 mm long
|
Weight
|
2.2 kg
|
Protection Class
|
IP68
|
Enclosure Material
|
Black Acetal Co-Polymer, 316 Stainless Steel, Glass
|
Seal Material
|
Polyurethane, Nitrile, with option of Viton
|
Cable Entry
|
Integral Cable Gland
|
Cable Length
|
10 metres standard, 100 metres maximum
|
Interface to Monitor
|
|
Power Supply
|
12 VDC from Monitor
|
Sensor Output
|
ModTechw², RS485
|
Environmental Data
|
|
Operating/Storage Temperature
|
0 to 50ºC
|
Location
|
Indoor/Outdoor
|
Pressure Rating
|
1 Bar or 14.5 psi
|
Maintenance
|
|
Service
|
Seal Service every 3500 cleans (application dependent)
|
Calibration
|
The sensor is inherently stable, calibration should be carried out to suit the application. Our recommendation is every 6 months.
|
Product Publication No. PPPAP/IT00010-18
Publication Date. 12 March 2018
Marketing Division
CV. Putra Andalas Prima
Tel. (+62)-61 8836 9476
Fax. (+62)-61 8836 9476
Email. marketing@putraandalasprima.co.id