Specification of

TurbiTechw² LS Suspended Solids and Turbidity Sensor

The TurbiTechw² LS Sensor is designed to monitor the levels of Suspended Solids or Turbidity typically found in Final Effluent from municipal and industrial wastewater treatment plants. It is also capable of monitoring solids in the intake to both effluent and drinking water treatment processes. The normal operating range is between 0 - 500 FTU, with versions of the sensor suitable for 0-100FTU and 0-1,000 FTU ranges available.

Monitoring of these key parameters requires sensors that are reliable and accurate, the TurbiTechw² LS fills this requirement perfectly. The large optical surfaces and sample volume ensure that the information provided by the sensor is both representative of the process and tolerant of fouling. In addition the sensor incorporates a self cleaning mechanism that ensures that the optical surfaces are kept clean at all times, the cleaning system is designed to avoid problems with ragging and does not smear the optical system. The cleaning system ensures that manual intervention on a routine basis is not required, the sensor should simply be checked as part of general site housekeeping.

The TurbiTechw² LS Sensor employs infrared light at 860nm using the 90° Light Scatter principle in accordance with ISO7027 (2000). The cleaning process is automatically initiated by the 7300w² Monitor at a user determined frequency. The cleaning process takes only 90 seconds, which means that the sensor is available for 99.5% of the time with a 5 hourly cleaning cycle.

APPLICATIONS

  • Final Effluent Turbidity
  • Final Effluent Solids
  • Inlet Solids
  • Primary Settled Sewage
  • Surface Water

MEASUREMENT PRINCIPAL

  • 90° Light Scatter
  • Wavelength 860nm
  • ISO 7027 Compliant

FEATURES

  • Fully automatic Self Cleaning
  • Flexible Mounting System
  • Large Optical Surface

BENEFITS

  • Automated Aeration Control
  • Low Cost of Ownership

COMPATIBLE MONITOR

  • 7300w² Monitor

Specification Data

Physical

Dimensions (hxwxd)

Ø80mm, 470 mm long

Weight

2.2 kg

Protection Class

IP68

Enclosure Material

Black Acetal Co-Polymer, 316 Stainless Steel, Glass

Seal Material

Polyurethane, Nitrile, with option of Viton

Cable Entry

Integral Cable Gland

Cable Length

10 metres standard, 100 metres maximum

Interface to Monitor

 

Power Supply

12 VDC from Monitor

Sensor Output

ModTechw², RS485

Environmental Data

 

Operating/Storage Temperature

0 to 50ºC

Location

Indoor/Outdoor

Pressure Rating

1 Bar or 14.5 psi

Maintenance

 

Service

Seal Service every 3500 cleans (application dependent)

Calibration

The sensor is inherently stable, calibration should be carried out to suit the application. Our recommendation is every 6 months.

 

 

Product Publication No. PPPAP/IT00009-18
Publication Date. 12 March 2018
Marketing Division
CV. Putra Andalas Prima
Tel. (+62)-61 8836 9476
Fax. (+62)-61 8836 9476
Email. marketing@putraandalasprima.co.id

Ulasan

/5
Ulasan
5
4
3
2
1

Foto dari Pembeli

Ulasan dari Pembeli

Filter
Semua
Dengan Foto
5
4
3
2
1
Telepon
Request a Quote
Produk Siap di Pesan
Rp 0
1
Bendera Indonesia Indonesia  |  Bendera Inggris English
Ingin menghubungi kami?
Klik tombol dibawah
Logo IDT
Chatbot